Resources search

A high prevalence of manual wheelchair rear-wheel misalignment could be leading to increased risk of repetitive strain injuries

OTT, Joseph
HENDERSON, Travis
WILSON-JENE, Holly
KOONTZ, Alicia
PEARLMAN, Jonathan
2021

Expand view

Purpose: To determine the prevalence and severity of manual wheelchair rear wheel misalignment in community-dwelling manual wheelchair users and estimate the associated increases in rolling resistance (RR) and risk of repetitive strain injuries (RSIs).


Materials and Methods: Data were collected in an outpatient rehabilitation clinic, a university research laboratory, and at adaptive sporting events in the United States. Two hundred active, self-propelling man- ual wheelchair users were recruited. Angular misalignment (referred to as toe angle) while the wheelchair was loaded with the user, and the difference between the maximum and minimum toe angle (referred to as slop) with the wheelchair unloaded.

 

Results: Average results for toe angle and slop (movement in the rear wheels) were 0.92 and 0.61 degrees, respectively. Using a lab-based testing method, we quantified the impact of increased RR forces due to misalignment in increased RR forces. Our results indicate that the average toe angle while under load and slop, without loading, measured in the community increase required propulsion force by 3.0 N. Combined toe angle and slop (i.e., the worst-case scenario) added increased propulsion force by 3.9 N. Conclusions: We found that rear-wheel misalignment was prevalent and severe enough that it may increase the risk for RSIs and decrease participation. To mitigate this issue, future work should focus on reducing misalignment through improved maintenance interventions and increased manufacturing qual- ity through more stringent standards.

The influence of a contoured seating base on pressure distribution and discomfort

DE MARE, Lieke
DE GROOT, Bas
DE KONING, Fleur
GEERS, Richard
TETTEROO, Daniel
2021

Expand view

Purpose: This research paper examines how contouring of a wheelchair seating base can help prevent pressure sores by distributing pressure over the buttocks. Contouring wheelchair cushioning is already done to some extent and has proved to be beneficial for pressure distribution. We researched the effect of contouring the seating base, and whether contouring the seating base affects effectiveness in pressure distribution and perceived discomfort.

 

Materials & methods: 13 healthy participants performed a within-subject experiment with three differ- ently contoured seating bases. Perceived comfort and seating pressure were measured for each condition.
Results: Results indicate that a more contoured base is positive for both comfort and increased pressure distribution.

 

Conclusions: Contoured seating bases can provide increased comfort and improved pressure distribution over flat seating bases. Future research should examine the effect of contouring on stability, as well as compare the effects of contoured seating bases and contoured cushions.

Design journey of an affordable manual standing wheelchair

SHAIKH-MOHAMMED, Javeed
DASH, Swostik Sourav
SARDA, Vivek
SUJATHA, S
2021

Expand view

Purpose: Only 1 in 10 people with disabilities can access assistive devices, underlining the critical need for low-cost assistive products. This paper describes the design evolution of a manual user-operated standing wheelchair (SWC), translating from prototype to product.


Methods: The SWC design has been refined over 5 years through multiple iterations based on comments from user trials. The SWC product, Arise, provides standing functionality, facile outdoor mobility, afford- ability, customisability, and is aesthetically pleasing. A one-time fitting and training ensure optimal effort for operation, correct posture, and comfortable user experience. The SWC accommodates users of differ- ent sizes and body weights (up to 110kg) and minimises user effort with the use of a gas spring. Incorporating discrete adjustments enables customisation while retaining the advantages of mass manu- facturing, which is necessary for ensuring affordability.

 

Results: The SWC has been field-tested and well received by over 100 wheelchair users, and Arise was launched recently by the industry partner.


Conclusions: It should be noted that RESNA cautions on the use of any standing device without medical consultation. Nevertheless, with appropriate dissemination and awareness, it is anticipated that the afford- able SWC product, Arise, will immensely benefit the eligible users and make a difference in their quality of life.

Wheelchair service provision education for healthcare professional students, healthcare personnel and educators across low- to high-resourced settings: a scoping review protocol

KAMALAKANNAN, Sureshkumar
RUSHTON, Paula W
GIESBRECHT, Ed
RUSAW, David F
BOUZIANE, Selsabil-A
NADEAU, Melodie
MCKEE, Jennifer
GOWRAN, Rosemary J
KIRBY, R L
PEDERSEN, Jessica P
TASIEMSKI, Tomasz
BURROLA-MENDEZ, Yohali
TOFANIN, Marco
GOLDBERG, Mary
PEARLMAN, Jon
2020

Expand view

Purpose

Appropriate wheelchair provision is necessary for addressing participation barriers experienced by individuals with mobility impairments. Health care professionals involved in the wheelchair service provision process require a specific set of skills and knowledge to enable wheelchair use that meets individual posture, mobility and daily living requirements. However, inconsistencies exist in academic programmes globally about providing comprehensive education and training programmes. The planned scoping review aims to review and synthesize the global literature on wheelchair service provision education for healthcare professional students, healthcare personnel and educators offered by universities, organizations and industries.

 

Methods

This scoping review will be guided by the Joanna Briggs Institute (JBI) methodological framework. Comprehensive literature searches will be conducted on various global electronic databases on health to seek out how wheelchair service provision education is organized, integrated, implemented and evaluated. Two independent reviewers will perform eligibility decisions and key data extractions. Data from selected studies will be extracted and analysed using conventional content analysis. Information related to wheelchair service provision education including curriculum development, content, teaching methods, evaluation and models of integration will be synthesized.

 

Implications and dissemination

The planned scoping review will be the first to examine all aspects of wheelchair service provision education across professionals, settings and countries. We anticipate that results will inform the content of a Wheelchair Educators’ Package, and if appropriate, a follow-up systematic review. An article reporting the results of the scoping review will be submitted for publication to a scientific journal.

Quality of wheelchair services as perceived by users in rural Bangalore district, India: a cross-sectional survey

GEILEN, Bart G
DE WITTE, Luc
NORMAN, Gift
GEORGE, Carolin Elizabeth
2020

Expand view

Background and aim:

This study investigated the current state of wheelchair services in Bangalore Rural district, as provided by Bangalore Baptist Hospital, and identified areas for improvement.

 

Method:

a cross-sectional survey was held among 50 wheelchair users. Data was collected on demographics, satisfaction, wheelchair skills and level of disability using QUEST, WST-Q and CHART-SF questionnaires.

 

Result:

Overall satisfaction can be described as more or less satisfied, scoring 3.8 out of 5. Wheelchair users were less satisfied with the services compared to the wheelchair itself. The skills a wheelchair users had were strongly correlated with satisfaction scores (p < 0.01). Differences in satisfaction between genders were observed and related to multiple factors.

 

Conclusion:

Wheelchairs should be easy to use with support services being easily accessible. A wheelchair should be delivered together with a training program to provide the user with the skills to operate and maintain the wheelchair. There are gender-wise differences in satisfaction towards wheelchair services that influence satisfaction.

Recommendations for studies on dynamic arm support devices in people with neuromuscular disorders: a scoping review with expert-based discussion

ESSERS, J M N
MURGIA, A
PETERS, A A
JANSSEN, M M H P
MEIJER, K
2020

Expand view

Purpose

Neuromuscular disorders are characterised by muscle weakness that limits upper extremity mobility, but can be alleviated with dynamic arm support devices. Current research highlights the importance and difficulties of evidence-based recommendations for device development. We aim to provide research recommendations primarily concerning upper extremity body functions, and secondarily activity and participation, environmental and personal factors.

 

Methods

Evidence was synthesised from literature, ongoing studies, and expert opinions and tabulated within a framework based on a combination of the International Classification of Functioning, Disability and Health (ICF) model and contextual constructs.

 

Results

Current literature mostly investigated the motor capacity of muscle function, joint mobility, and upper body functionality, and a few studies also addressed the impact on activity and participation. In addition, experts considered knowledge on device utilisation in the daily environment and characterising the beneficiaries better as important. Knowledge gaps showed that ICF model components and contextual constructs should be better integrated and more actively included in future research.

 

Conclusions

It is recommended to, first, integrate multiple ICF model components and contextual constructs within one study design. Second, include the influence of environmental and personal factors when developing and deploying a device. Third, include short-term and long-term measurements to monitor adaptations over time. Finally, include user satisfaction as guidance to evaluate the device effectiveness.

Novel lateral transfer assist robot decreases the difficulty of transfer in post-stroke hemiparesis patients: a pilot study

KOYAMA, Soichiro
TANABE, Shigeo
OTAKA, Yohei
KATO, Tomoya
FURUZAWA, Shotaro
TATEMOTO, Tsuyoshi
KUMAZAWA, Nobuhiro
YOSHIMUTA, Hiroshi
TORII, Katsuhiko
TSUKADA, Shingo
SAITOH, Eiichi
et al
2020

Expand view

Purpose

The purpose of this study was to clarify whether the novel lateral transfer assist robot facilitates easier transfers compared with a wheelchair in post-stroke hemiparesis patients.

 

Methods

This cross-sectional study enrolled 20 post-stroke hemiparesis patients, and the task difficulty of transfers was compared between a wheelchair and lateral transfer assist robot. All participants were asked to transfer from either wheelchair or lateral transfer assist robot to a platform table and back. The primary outcome was the transfer score of the Functional Independence Measure. The secondary outcome was the time required for transfer.

 

Results

The transfer score of the Functional Independence Measure was significantly higher with lateral transfer assist robot than with wheelchair (p < .001). The transfer times from these devices to a platform table and back showed no significant differences (to device from platform table: 7.8 s, lateral transfer assist robot vs 7.6 s, wheelchair, p > .05: device to platform table: 7.1 s, lateral transfer assist robot vs 8.0 s, wheelchair, p > .05).

 

Conclusions

Transfer with a lateral transfer assist robot is easier than with wheelchair and facilitates independence in post-stroke hemiparesis patients.

The value of powered mobility scooters from the perspective of elderly spouses of the users – a qualitative study

FREDRIKSSON, Carin
PETTERSSON, Ingvor
HAGBERG, Lars
HERMANSSON, Liselotte
2020

Expand view

Purpose

To explore spouses’ experiences of the value of mobility scooters prescribed to their partner.

 

Material and Methods

A descriptive design with a qualitative approach was used. Thirteen spouses (11 females) aged 65–86 years participated. Semi-structured interviews were conducted when the spouse’s partner had had the mobility scooter for 4–6 months. The interviews were analysed using qualitative content analysis.

 

Results

The interviews showed primarily that the spouses experienced that their everyday lives and life situation had improved since their partner had received a mobility scooter. They reported that they could engage in activities of their own choice to a greater extent. The prescription of a mobility scooter to their partner had also yielded a sense of freedom related to shared activities. On the other hand, the spouses described some of the scooter’s limitations. Three categories emerged: a sense of freedom related to the spouse’s own activities, a sense of freedom related to shared activities and a somewhat restricted freedom.

 

Conclusion

Prescription of a powered mobility scooter was of value to the users’ spouses because it facilitated independent and shared activities and participation in the community. The value was mainly expressed as a sense of freedom when doing things on their own or together with their partner. Spouses are key persons in the rehabilitation of people with mobility restrictions. Their views on the assistive device may influence the rehabilitation process. Knowledge of spouses’ experiences is thus crucial, as this may influence the future rehabilitation outcome.

Undergraduate physiotherapy students’ basic wheelchair provision knowledge: a pilot study in two universities in Colombia

TORO-HERNÁNDEZ, María Luisa
MONDRAGÓN-BARRERA, Mónica Alejandra
TORRES-NARVÁEZ, Martha Rocío
VELASCO-FORERO, Sandra Esperanza
GOLDBERG, Mary
2019

Expand view

Purpose: 

Access to an appropriate wheelchair is a human right. Only between 5–15% of people who need a wheelchair have access to one. One of the key barriers to access is the lack of appropriately trained rehabilitation professionals. The objective of this study was to evaluate basic manual wheelchair provision knowledge in final-year physiotherapy undergraduate students in two programs in Colombia.

 

Materials and methods: 

Students took the International Society of Wheelchair Professionals Wheelchair Service Provision – Basic Test which was administered online and in Spanish. The minimum score to pass the test is 70%; it assesses seven domains: Assessment; Prescription; Products; Fitting; User training; Follow-up, maintenance, and repairs; and Process.

 

Results and conclusions

One-hundred sixteen students took the test and no one passed the test. The highest median domain scores were in Assessment and Process while the lowest were in Fitting and Products. The limitations of this study include that this sample does not represent all physiotherapy programmes or students in Colombia, there may be potential errors in the Spanish translation of the outcome measure, and students encountered Internet connectivity issues during the test that may have impacted their scores. Immediate interventions are required to improve teaching and students’ learning outcomes related to basic manual wheelchair provision in these two programs. This study may serve as a foundation for future regional or national studies that assess the situation of wheelchair provision training in rehabilitation programs that will inform improvement actions. This manuscript is also available in Spanish as Supplemental Material.

Mobility Analysis of AmpuTees (MAAT 4): classification tree analysis for probability of lower limb prosthesis user functional potential

WURDEMAN, Shane R
STEVENS, Phillip M
CAMPBELL, James H
2019

Expand view

Purpose: 

To develop a predictive model to inform the probability of lower limb prosthesis users’ functional potential for ambulation.

 

Materials and Methods: 

A retrospective analysis of a database of outcomes for 2770 lower limb prosthesis users was used to inform a classification and regression tree analysis. Gender, age, height, weight, body mass index adjusted for amputation, amputation level, cause of amputation, comorbid health status and functional mobility score [Prosthetic Limb Users Survey of Mobility (PLUS-M™)] were entered as potential predictive variables. Patient K-Level was used to assign dependent variable status as unlimited community ambulator (i.e., K3 or K4) or limited community/household ambulator (i.e., K1 or K2). The classification tree was initially trained from 20% of the sample and subsequently tested with the remaining sample.

 

Results: 

A classification tree was successfully developed, able to accurately classify 87.4% of individuals within the model’s training group (standard error 1.4%), and 81.6% within the model’s testing group (standard error 0.82%). Age, PLUS-M™ T-score, cause of amputation and body weight were retained within the tree logic.

 

Conclusions: 

The resultant classification tree has the ability to provide members of the clinical care team with predictive probabilities of a patient’s functional potential to help assist care decisions.

Development, reliability, and piloting of a wheelchair caster failure inspection tool (C-FIT)

MHATRE, Anand A
LACHELL, Stephanie
PEARLMAN, Jonathan L
2019

Expand view

Introduction: 

Wheelchair casters fail frequently in the field causing multiple user consequences and wheelchair breakdowns. To inform caster design improvement, there exists no validated tools that can collect caster failures. This need motivated the development of a user-reported, caster failure inspection tool (C-FIT).

 

Methods: 

To develop C-FIT, a multistep design and testing approach was used which included face validity testing, test-retest reliability testing and expert review. Reliability testing was conducted with two independent cohorts of wheelchair professionals who inspected caster failures physically and online through pictures. The tool was revised based on testing outcomes and expert feedback. For preliminary data collection and evaluating usability, C-FIT was piloted at wheelchair service centers in Scotland, Indonesia and Mexico.

 

Results: 

Caster failure items reported in the literature were screened to develop the initial list of C-FIT items. Face validity testing conducted through surveys with wheelchair experts (n = 6) provided 14 items for C-FIT inclusion. The test-retest reliability was found to be high for 10 items with physical failure inspections (n = 12). For each of these items, 75% or more participants had substantial to almost perfect agreement scores (κ = 0.6–1.0). Lower reliability scores were found with online failure inspections (n = 11). C-FIT received positive usability feedback from study participants and data collectors in the field. Pilot field data (n = 31) included comprehensive details about failures useful for manufacturers, designers and researchers to improve caster designs.

Conclusions: 

The C-FIT tool developed in this study has substantial reliability and can be used for documenting caster failures at wheelchair service centers.

Adaptations from the prosthetic and intact limb during standing on a sway-referenced support surface for transtibial prosthesis users

RUSAW, David F
2018

Expand view

Purpose: 

To investigate the bilateral postural adaptations as a result of standing on an increasingly unstable sway-referenced support surface with both the intact and prosthetic limb for transtibial prosthesis users (TPUs).

 

Method: 

TPUs (n = 14) and matched controls (n = 14) stood quietly in multiple foot placement conditions (intact foot, prosthetic foot and both feet) on a sway-referenced support surface which matched surface rotation to the movement of the centre of pressure (CoP). Force and motion data were collected and used to analyse CoP mean position, displacement integral and force components under intact and prosthetic limbs.

 

Results: 

Significant differences were found between prosthesis users and controls in CoP mean position in anteroposterior (1.5 (95% CI, 1.2–1.8) cm) and mediolateral directions (3.1 (95% CI, 0.5–5.7) cm. CoP displacement integrals were significantly different greater for prosthesis user group in the anteroposterior direction. Force components differences were found in all planes (anteroposterior: 0.6 (95% CI, 0.4–0.8 N); mediolateral: 0.1 (95% CI, 0.0–0.2 N & 0.3 (95% CI, 0.2–0.4) N, inferosuperior: 2.2 (95% CI, 1.4–3.0) N).

 

Conclusions: 

TPUs have bilateral static and dynamic postural adaptations when standing on a sway-referenced support surface that is different to controls, and between prosthetic and intact sides. Results further support evidence highlighting importance of the intact limb in maintenance of postural control in prosthesis users. Differences indicate clinical treatment should be directed towards improving outcomes on the intact side.

Kinect4FOG: monitoring and improving mobility in people with Parkinson’s using a novel system incorporating the Microsoft Kinect v2

AMINI, Amin
BANITSAS, Konstantinos
YOUNG, William R
2018

Expand view

Parkinson’s is a neurodegenerative condition associated with several motor symptoms including tremors and slowness of movement. Freezing of gait (FOG); the sensation of one’s feet being “glued” to the floor, is one of the most debilitating symptoms associated with advanced Parkinson’s. FOG not only contributes to falls and related injuries, but also compromises quality of life as people often avoid engaging in functional daily activities both inside and outside the home. In the current study, we describe a novel system designed to detect FOG and falling in people with Parkinson’s (PwP) as well as monitoring and improving their mobility using laser-based visual cues cast by an automated laser system. The system utilizes a RGB-D sensor based on Microsoft Kinect v2 and a laser casting system consisting of two servo motors and an Arduino microcontroller. This system was evaluated by 15 PwP with FOG. Here, we present details of the system along with a summary of feedback provided by PwP. Despite limitations regarding its outdoor use, feedback was very positive in terms of domestic usability and convenience, where 12/15 PwP showed interest in installing and using the system at their homes.

Speech and language pathologists’ perceptions and practises of communication partner training to support children’s communication with high-tech speech generating devices

TEGLER, Helena
PLESS, Mia
JOHANSSON, Monica Blom
SONNANDER, Karin
2018

Expand view

Purpose: 

This study examined speech and language pathologists’ (SLPs’) perceptions and practices of communication partner training with high-tech speech generating devices (SGDs).

 

Method: 

Fifteen SLPs were recruited throughout Sweden. The SLPs answered a study-specific questionnaire on communication partner training in relation to communication partners to children with severe cerebral palsy and intellectual disability. The results were analysed with descriptive statistics (closed-ended questions, responses on Likert scales) and content analysis (open-ended question) using ICF-CY.

 

Results:

Twelve SLPs completed the survey. Half had no or one training session with communication partners in the last year. One-third never used documents for goal-setting. Half seldom or never taught communication partner strategies. Three quarters only used verbal instructions. The main obstacles were environmental factors.

 

Conclusions

This study contributes valuable knowledge about high-tech SGD interventions targeting communication partners. The high-tech SGD intervention may benefit from goal-setting, extended number of training sessions and a range of instructional approaches.

Development and functional demonstration of a wireless intraoral inductive tongue computer interface for severely disabled persons

STRUIJK, Lotte N S Andreasen
LONTIS, Eugen R
GAIHEDE, Michael
CALTENCO, Hector A
LUND, Morten Enemark
SCHIOELER, Henrik
BENTSEN, Bo
2016

Expand view

Purpose: Individuals with tetraplegia depend on alternative interfaces in order to control computers and other electronic equipment. Current interfaces are often limited in the number of available control commands, and may compromise the social identity of an individual due to their undesirable appearance. The purpose of this study was to implement an alternative computer interface, which was fully embedded into the oral cavity and which provided multiple control commands.

 

Methods: The development of a wireless, intraoral, inductive tongue computer was described. The interface encompassed a 10-key keypad area and a mouse pad area. This system was embedded wirelessly into the oral cavity of the user. The functionality of the system was demonstrated in two tetraplegic individuals and two able-bodied individuals

 

Results: The system was invisible during use and allowed the user to type on a computer using either the keypad area or the mouse pad. The maximal typing rate was 1.8 s for repetitively typing a correct character with the keypad area and 1.4 s for repetitively typing a correct character with the mouse pad area.

 

Conclusion: The results suggest that this inductive tongue computer interface provides an esthetically acceptable and functionally efficient environmental control for a severely disabled user.

Development of a contextually appropriate, reliable and valid basic Wheelchair Service Provision Test

GARTZ, Rachel
GOLDBERG, Mary
MILES, Alexandria
MILES, Rory
PEARLMAN, Jon
SCHMELER, Mark
BITTMAN, Sarah Jonassen
HALE, Judith
2016

Expand view

Purpose:

Currently, there is no internationally accepted way to measure the competency of wheelchair service professionals. The International Society of Wheelchair Professionals aims to develop a Wheelchair Service Provision – Basic Test as a preliminary step towards establishing a certification process. 

 

Method:

A team of wheelchair service provision experts developed test questions and conducted alpha and beta testing in order to validate them. Low-performing test items were eliminated. A pilot test was then conducted, which focused on developing a pass score, determining language barriers and validating the test as a measure of competency. 

 

Results:

90 participants completed one of three versions of the Wheelchair Service Provision – Basic Test. A pass score of 70% was established and 135 questions were accepted for the final test. Analysis of variance indicated there was a difference in scores based on language (p = 0.001), but not based on experience level. This result motivated translation in to the United Nations’ official languages.

 

Conclusions:

The results indicate that the Wheelchair Service Provision – Basic Test is a valid method for measuring basic competency of wheelchair professionals. Additionally, researchers recommend a skills assessment to help to ensure only qualified wheelchair professionals receive the certificate.

The African disability scooter: efficiency testing in paediatric amputees in Malawi

BECKLES, Verona
MCCAHILL, Jennifer L
STEBBINS, Julie
MKANDAWIRE, Nyengo
CHURCH, John C T
LAVY, Chris
2014

Expand view

Purpose:

The African Disability Scooter (ADS) was developed for lower limb amputees, to improve mobility and provide access to different terrains. The aim of this study was to test the efficiency of the ADS in Africa over different terrains.

 

Method: 

Eight subjects with a mean age of 12 years participated. Energy expenditure and speed were calculated over different terrains using the ADS, a prosthetic limb, and crutches. Repeated testing was completed on different days to assess learning effect. 

 

Results:

Speed was significantly faster with the ADS on a level surface compared to crutch walking. This difference was maintained when using the scooter on rough terrain. Oxygen cost was halved with the scooter on level ground compared to crutch walking. There were no significant differences in oxygen consumption or heart rate. There were significant differences in oxygen cost and speed between days using the scooter over level ground, suggesting the presence of a learning effect. 

 

Conclusions:

This study demonstrates that the ADS is faster and more energy efficient than crutch walking in young individuals with amputations, and should be considered as an alternative to a prosthesis where this is not available. The presence of a learning effect suggests supervision and training is required when the scooter is first issued.

The psychosocial impact on standing devices

NORDSTRÖM, Birgitta
NYBERG, Lars
EKENBERG, Lilly
NÄSLUND, Annika
2013

Expand view

Purpose:

The aim of this study was to explore the psychosocial impact of standing devices as experienced by users. 

 

Method:

This is the second part of a comprehensive survey in five counties in Sweden where all the subjects with standing devices were invited to participate. The impact of standing devices on functional independence, quality of life and wellbeing was assessed using a questionnaire, Psychosocial Impact of Assistive Devices Scale (PIADS).

 

Results:

The psychosocial impact of the standing devices was perceived as positive. The highest PIADS scores in relation to age were found in the oldest group, aged 65 years and older. The ability to walk and independence in ambulation resulted in higher scores than the use of a wheelchair and/or dependence on others. Those who stood often awarded higher scores in the PIADS questionnaire compared to those who used the device less frequently. When standing was integrated in various activities, its psychosocial impact received high scores. 

 

Conclusion:

The psychosocial impact of standing devices was generally experienced positively. The main results indicated that standing in a standing device had a value and we as professionals should ask the users about the intended purpose of their standing in order to prescribe the optimal device.

E-bulletin